Event code
Event name
54015456 hex
Motion Control
Instruction Re-exe-
cution Disabled
(Execution Mode)
54015457 hex
Motion Control
Instruction Re-exe-
cution Disabled
(Axes Group Spec-
ification)
54015458 hex
Motion Control
Instruction Re-exe-
cution Disabled
(Jerk Setting)
54015459 hex
Motion Control
Instruction Re-exe-
cution Disabled
(Master Axis)
5401545A hex
Motion Control
Instruction Re-exe-
cution Disabled
(MasterOffset)
5401545B hex
Motion Control
Instruction Re-exe-
cution Disabled
(MasterScaling)
5401545C hex
Motion Control
Instruction Re-exe-
cution Disabled
(MasterStartDis-
tance)
5401545D hex
Motion Control
Instruction Re-exe-
cution Disabled
(Continuous)
NJ-series Troubleshooting Manual (W503)
Meaning
An attempt was made to
• A parameter for an
change the parameter for
the Periodic input variable
when re-executing a motion
control instruction. (This
input variable cannot be
changed when re-executing
an instruction.)
An attempt was made to
• A parameter for an
change the parameter for
the AxesGroup input vari-
able when re-executing a
motion control instruction.
(This input variable cannot
be changed when re-exe-
cuting an instruction.)
An attempt was made to
• A parameter for an
change the parameter for
the Jerk input variable
when re-executing a motion
control instruction. (This
input variable cannot be
changed when re-executing
an instruction.)
An attempt was made to
• A parameter for an
change the parameter for
the Master input variable
when re-executing a motion
control instruction. (This
input variable cannot be
changed when re-executing
an instruction.)
An attempt was made to
• A parameter for an
change the parameter for
the MasterOffset input vari-
able when re-executing a
motion control instruction.
(This input variable cannot
be changed when re-exe-
cuting an instruction.)
• A parameter for an
An attempt was made to
change the parameter for
the MasterScaling input
variable when re-executing
a motion control instruction.
(This input variable cannot
be changed when re-exe-
cuting an instruction.)
An attempt was made to
• A parameter for an
change the parameter for
the MasterStartDistance
input variable when re-exe-
cuting a motion control
instruction. (This input vari-
able cannot be changed
when re-executing an
instruction.)
An attempt was made to
• A parameter for an
change the parameter for
the Continuous input vari-
able when re-executing a
motion control instruction.
(This input variable cannot
be changed when re-exe-
cuting an instruction.)
Assumed cause
Maj
Prt
input variable that can-
not be changed for re-
execution was
changed.
input variable that can-
not be changed for re-
execution was
changed.
input variable that can-
not be changed for re-
execution was
changed.
input variable that can-
not be changed for re-
execution was
changed.
input variable that can-
not be changed for re-
execution was
changed.
input variable that can-
not be changed for re-
execution was
changed.
input variable that can-
not be changed for re-
execution was
changed.
input variable that can-
not be changed for re-
execution was
changed.
3 Error Tables
Level
Refer-
ence
Min
Obs
Info
S
NJ-series
Instruc-
tions Ref-
erence
Manual
(Cat. No.
W502)
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
3-33
3

Advertisement

Table of Contents
loading

Table of Contents