3 Error Tables
Event code
Event name
64440000 hex
Negative
Limit Input
74220000 hex
Servo Main
Circuits OFF
57220000 hex
Actual Posi-
(Ver. 1.06)
tion Over-
flow/Underflo
w
57230000 hex
Switch Struc-
(Ver. 1.06)
ture Track
Number Set-
ting Out of
Range
57240000 hex
Switch Struc-
(Ver. 1.06)
ture First ON
Position Set-
ting Out of
Range
57250000 hex
Switch Struc-
(Ver. 1.06)
ture Last ON
Position Set-
ting Out of
Range
57260000 hex
Switch Struc-
(Ver. 1.06)
ture Axis
Direction Out
of Range
57270000 hex
Switch Struc-
(Ver. 1.06)
ture Cam
Switch Mode
Out of Range
57280000 hex
Switch Struc-
(Ver. 1.06)
ture Duration
Setting Out of
Range
3-72
Meaning
Assumed cause
An instruction for a
• An instruction for a motion in
motion in the nega-
the negative direction was exe-
tive direction was
cuted when the negative limit
executed when the
input was ON, or an instruction
negative limit input
for a motion with no direction
was ON.
specification was executed
when the negative limit input
was ON. An axes group motion
control instruction was exe-
cuted when the negative limit
input was ON.
An attempt was
• An attempt was made to turn
made to turn ON
ON the Servo when the main
the Servo when the
circuit power supply to the
main circuit power
Servo Drive was OFF.
supply to the Servo
Drive was OFF.
An instruction was
• An instruction was executed
executed that is not
that is not supported during an
supported during
actual position overflow or
an actual position
underflow.
overflow/underflow.
The value of Track-
• The value of the member of the
Number that is
structure variable that was
specified in the
specified for the in-out variable
Switches in-out
of the instruction is out of
variable to a motion
range.
control instruction is
out of range.
The value of Fir-
• The value of the member of the
stOnPosition that is
structure variable that was
specified in the
specified for the in-out variable
Switches in-out
of the instruction is out of
variable to a motion
range.
control instruction is
out of range.
• The value of the member of the
The value of Last-
OnPosition that is
structure variable that was
specified in the
specified for the in-out variable
Switches in-out
of the instruction is out of
variable to a motion
range.
control instruction is
out of range.
The value of Axis-
• The value of the member of the
Direction that is
structure variable that was
specified in the
specified for the in-out variable
Switches in-out
of the instruction is out of
variable to a motion
range.
control instruction is
out of range.
The value of Cam-
• The value of the member of the
SwitchMode that is
structure variable that was
specified in the
specified for the in-out variable
Switches in-out
of the instruction is out of
variable to a motion
range.
control instruction is
out of range.
The value of Dura-
• The value of the member of the
tion that is specified
structure variable that was
in the Switches in-
specified for the in-out variable
out variable to a
of the instruction is out of
motion control
range.
instruction is out of
range.
Level
Maj
Prt
Min
Obs Info
S
NJ-series
Motion Con-
trol Instruc-
tions
Reference
Manual (Cat.
No. W508)
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
NJ-series Troubleshooting Manual (W503)