Errors In Slave Terminals - Omron NJ Series Troubleshooting Manual

Sysmac machine automation controller
Hide thumbs Also See for NJ Series:
Table of Contents

Advertisement

Event code
Event name
54013012 hex
DB Connec-
(Ver. 1.05)
tion Instruc-
tion
Execution
Timeout
54013013 hex
DB Connec-
(Ver. 1.05)
tion Service
Error Stop
54013014 hex
Data Already
(Ver. 1.05)
Spooled
54013015 hex
DB Connec-
tion Service
(Ver. 1.05)
Initializing
54013016 hex
DB in Pro-
(Ver. 1.05)
cess
54013017 hex
Operation
(Ver. 1.05)
Log Disabled
3-1-7

Errors in Slave Terminals

The section provides tables of the errors (events) that can occur in the following Units in OMRON Slave
Terminals.
• NX-series EtherCAT Coupler Units
• NX-series Digital I/O Units
• NX-series Analog I/O Units
• NX-series System Units
• NX-series Position Interface Units
• NX-series Safety Control Units
NJ-series Troubleshooting Manual (W503)
Meaning
Assumed cause
The instruction was
• The power supply to the server
not completed
is OFF.
within the time
• The Ethernet cable connector is
specified for time-
disconnected.
out.
• The Ethernet cable is broken.
• The server's processing time is
long.
The instruction
• The DB Connection settings
could not be exe-
are corrupted.
cuted because the
DB Connection
Service was
stopped due to an
error.
One or more SQL
• A DB_Insert or DB_Update
statements are
instruction was executed when
already stored in
one or more SQL statements
the Spool memory.
were already stored in the
Spool memory.
• A DB_Select or DB_Delete
instruction was executed when
one or more SQL statements
were already stored in the
Spool memory.
The instruction
• The relevant instruction was
could not be exe-
executed during the initializa-
cuted because the
tion processing of the DB Con-
initialization pro-
nection Service.
cessing of the DB
Connection Ser-
vice is in progress.
The instruction
• Though a DB Connection
could not be exe-
Instruction Execution Timeout
cuted because the
occurred for the previous
DB is under pro-
instruction, the relevant instruc-
cessing in the
tion was executed before com-
pletion of the DB's processing
server.
in the server.
The log could not
• Though Execution Log was
be recorded
specified in the LogType input
because the speci-
variable, the Execution Log is
fied Operation Log
disabled.
is disabled.
• Though Debug Log was speci-
fied in the LogType input vari-
able, recording to the Debug
Log is stopped.
3 Error Tables
Level
Maj
Prt
Min
Obs
Info
S
NJ-series
Database
Connection
CPU Units
User's Manual
(Cat. No.
W527)
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
Reference
3
3-87

Advertisement

Table of Contents
loading

Table of Contents