3 Error Tables
Event code
Event name
54010413 hex
Undefined CJ-
series Memory
Address
54010414 hex
Stack Underflow
54010416 hex
Illegal Number of
Array Elements or
Dimensions
54010417 hex
Specified Task
Does Not Exist
54010418 hex
Unallowed Task
Specification
54010419 hex
Incorrect Data
Type
5401041A hex
Multi-execution of
Instructions
5401041B hex
Data Capacity
(Ver. 1.02)
Exceeded
5401041C hex
Different Data
(Ver. 1.04)
Sizes
5401041D hex
Exceeded Simulta-
(Ver. 1.05)
neous Instruction
Executed
Resources
54010800 hex
FINS Error
54010801 hex
FINS Port Already
in Use
3-18
Meaning
The required specification
• The required AT speci-
is missing for a variable for
which CJ-series Unit mem-
ory must be specified.
There is no data in a stack.
• An attempt was made
The valid range was
• The valid range was
exceeded for the number of
array elements or dimen-
sions in an array I/O param-
eter for an instruction.
The task specified for the
• The specified task
instruction does not exist.
An unallowed task was
• The local task, the pri-
specified for an instruction.
A data type that cannot be
• A data type that can-
used for an instruction is
specified for an input or in-
out variable.
Multi-execution was speci-
• Execution of an
fied for an instruction that
does not support it.
Processing was not possi-
• Data that exceeded
ble because the data that
was passed to the instruc-
tion was too large.
The size of the data speci-
• Data of a size that is
fied for instruction input or
in-out data is different from
the size of the target
parameter.
The maximum resources
• More than the maxi-
that you can use for the rel-
evant instruction group at
the same time was
exceeded.
An error occurred when a
• An error occurred
FINS command was sent
or received.
The FINS port is being
• The FINS port is being
used.
Assumed cause
Maj
Prt
fication is missing for a
variable for which CJ-
series Unit memory
must be specified.
to read data from a
stack that contains no
data.
exceeded for the num-
ber of array elements
or dimensions in an
array I/O parameter for
an instruction.
does not exist.
mary periodic task, or
a periodic task was
specified.
not be used for an
instruction is specified
for an input or in-out
variable.
instruction that does
not support multi-exe-
cution of instructions
was specified more
than once.
the size that can be
processed was
passed to an instruc-
tion.
different from the size
of the target parame-
ter was specified for
the input or in-out data
of an instruction.
mum number of rele-
vant instructions were
executed at the same
time. The maximum
number of instruc-
tions for the relevant
instruction group is as
follows:
• DB connection
instructions: 32
when a FINS com-
mand was sent or
received.
used.
NJ-series Troubleshooting Manual (W503)
Level
Refer-
ence
Min
Obs
Info
S
NJ-series
Instruc-
tions Ref-
erence
Manual
(Cat. No.
W502)
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.

Advertisement

Table of Contents
loading

Table of Contents