AEMC PowerPad 8436 User Manual page 94

3-phase power quality analyzer
Hide thumbs Also See for PowerPad 8436:
Table of Contents

Advertisement

Measurement ranges after application of the ratios
Measurement
RMS & RMS ½ voltage
Direct voltage (DC)
Peak voltage (PK)
RMS & RMS ½ current
Direct current (DC)
Peak current (PK)
Active power (P)
DC power (Pdc)
Reactive power (Q 1 )
non-active (N) and
distortion power (D)
Apparent power (S)
Active energy (Ph)
DC energy (Pdch)
Reactive energy (Q 1 h)
non-active (Nh) and
distortion energy (Dh)
Apparent energy (Sh)
(1) Energy corresponds to more than 22,000 years of the associated maximum power (maximum ratios).
(2) Energy Pdch corresponds to more than 1 million years at maximum power Pdc (maximum ratios).
(3) Maximum value calculated for a 2-wire single-phase connection (phase-to-ground voltage).
with minimum ratio(s)
simple
compound
simple
compound
simple
compound
Measurement range
Minimum
120 mV
120 mV
120 mV
120 mV
160 mV
320 mV
5 mA
10 mA
7 mA
600 µW
1.2 mW
600 µvar
600 µVA
1 mWh
1 mWh
1 mvarh
1 mVAh
94
Maximum
with maximum ratio(s)
170 GV
340 GV
200 GV
400 GV
240 GV
480 GV
300 kA
5 kA
420 kA
51 PW (3)
1 PW (3)
51 Pvar (3)
51 PVA (3)
9 999 999 EWh (1)
9 999 999 EWh (2)
9 999 999 Evarh (1)
9 999 999 EVAh (1)

Advertisement

Table of Contents
loading