Step
Operator Action
Programming the door operator
1.
Refer to Figure 36 and, at the base of
the controller, PRESS and HOLD the
"SELECT" and "ENTER" until LEDs 1
through 4 flash.
NOTE: The doors are shipped with a spring tension set to one half of maximum spring tension.
2.
With the door in the closed position,
PRESS the "ENTER" pushbutton.
3.
Open the door to its fully open position.
4.
With the door in the fully open
position, PRESS the "ENTER"
pushbutton.
5.
With the door in the fully closed
position, PRESS the "ENTER"
pushbutton.
To reset the controller, PERFORM the following:
6.
a. PRESS and HOLD the "ENTER" pushbutton.
b. PRESS and RELEASE the "RESET" pushbutton.
c. RELEASE the "ENTER" pushbutton.
7.
If further door adjustments are necessary, refer to Sections
Initializing the Remote Control
1.
To set RF switch with door controller,
PERFORM the following:
a. PUSH the "LEARN" switch on the controller.
b. PUSH the RF activation switch.
2.
To erase all activation codes learned in door controller,
PERFORM the following:
a. Press and hold the "LEARN" switch on the operator.
b. Press and release the "RESET" switch on the operator.
c. Release the "LEARN" switch.
• The operator shall enter program mode.
• The four LEDs on the circuit board shall repeatedly flash green.
• The "CLOSE POSITION" LED shall illuminate red and remain lit.
Always reprogram the operator after adjusting the door spring tension.
• The "CLOSE POSITION" lED shall flash green.
• The "OPEN POSITION" LED shall illuminate red indicating that
• The LED shall illuminate green once data has been stored for this
• The "OPEN POSITION" LED shall flash green.
• The "AUTO SETUP" position LED shall illuminate red indicating
• The LED shall illuminate green once data has been stored for this
• The door shall open quickly and then close slowly.
• The "AUTO SETUP" led shall illuminate green.
• The operator will store the settings and exit programming
the operator is ready for input.
parameter.
that the operator is ready for input.
parameter.
mode.
9 t
hrough 12 and PERFORM adjustment.
The controller will enter the learn mode for 15
seconds while green and red LEDs are
illuminated.
LED "CLOSE POSITION"shall flash green
indicating that the operator learned this RF
LED 1 through 4 will flash green.
43 of 50