Operator And Door Arm Installation Instructions - Push Side Applications - Assa Abloy 5800 ADAEZ PRO Installation And Operation Instructions Manual

Table of Contents

Advertisement

®
5800 ADAEZ PRO
Installation and Operation Instructions
6

Operator And Door Arm Installation Instructions - Push Side Applications

NOTE: Operator always mounts on inside of door at
hinge or pivot edge of top rail. Template provides for
Right Hand door mounting on one side and Left Hand
door mounting on opposite side.
The template has a solid-line outline and a dotted-line
outline. The solid-line outline is for narrow rail door. The
dotted line outline is for medium or wide rail doors.
Each template provides two additional hole slots. Use a
minimum of 4 mounting hole locations that will not
interfere with a top rail web, rail-to-stile tie rod(s), or
rail-to-stile junction.
1. SELECT right hand or left hand operator mounting
template as applicable.
2. EXAMINE inside door top rail and DETERMINE
top rail width (narrow, medium, or wide).
3. DETERMINE type of mounting hinge (butt or
continuous, center pivot, or offset.
Figure 6
Copyright © 2018, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights
reserved. Reproduction in whole or in part without the express written permission of ASSA
ABLOY Accessories and Door Controls Group, Inc. is prohibited.
Use this solid line mounting location
for narrow stile doors.
On an aluminum storefront door, the operator mounting
holes must not be drilled into the top rail web, rail-to-
stile tie rod(s), or the rail-to-stile junction.
4. If door is an aluminum storefront door, EXAMINE
top rail, and, when drilling mounting holes,
ENSURE the following:
• Do not drill into the top rail web
• Do not drill into the rail-to-stile tie rod(s)
• Do not drill into the rail-to-stile junction
5
Refer to Figures 6 and 9, and DETERMINE which
operator mounting template fold line to use as
follows:
a. MEASURE the stop thickness.
• If the stop is greater than 1-1/2" (38 mm),
USE the upper template fold line.
• If the stop is 1-1/2" (38 mm), or less, USE
the lower template fold line.
b. If the door is a narrow-stile door, USE the solid
line mounting location.
c. If the door is an application other than a narrow-
stile door, USE the dotted line mounting
location.
Use this dotted line mounting location
for all applications except narrow stile doors.
11 of 50
CAUTION
Use this fold line when door stop
width is greater than 1-1/2".
STOP GREATER
STOP GREATER
THAN 1-1/2"
THAN 1-1/2"
DOOR
Use this fold line when door stop
width is 1-1/2" or less.
STOP LESS THAN 1-1/2"
700002-Rev N 09/18