12
Setting Optional Functions (Power Close, Push & Go, Dynamic Braking, Latch Assist)
NOTE: The ADAEZ must be plugged in to the 24VDC
Class 2 transformer if the POWER CLOSE, PUSH AND
GO, or LATCH ASSIST features are enabled.
POWER CLOSE will apply a closing force on the door if
the door did not fully close in the normal closing time.
Power close will activate and turn off when the door is
fully closed or if the door does not move after
attempting to close for two seconds.
PUSH AND GO will cause the door operator to initiate
an automatic open cycle when the door is pushed in the
open direction.
DYNAMIC BRAKING will apply braking to the door
when the door speed exceeds four times the programed
automatic opening time under abusive opening
conditions or wind.
LATCH ASSIST will apply a force in the close direction
for 1/2 second when the operator receives an activate
signal to assist an electric strike in unlocking. When the
door closes the operator will apply a force in the close
direction to assist in latching the door.
1. ENABLE or DISABLE Power Close, Push & Go,
Dynamic Braking, or Latch Assist (factory default is
OFF for all features):
a. PRESS and HOLD "SELECT" and "ENTER" until
LEDs 1 through 4 flash green briefly.
• The "OPEN & CLOSE TIME" LED shall
illuminate.
b. PRESS and RELEASE the "SELECT"
pushbutton to advance until OPTIONS LED
illuminates and the LED above the desired
function lights.
• PC LED indicates POWER CLOSE
• PG LED indicates PUSH & GO
• DB LED indicates DYNAMIC BRAKING
• LA LED indicates LATCH ASSIST
NOTE: The LED color indicates the state of the
selected setting until the POTENTIOMETER is rotated.
A GREEN LED indicates the features is turned ON and
a RED LED indicates the feature is OFF.
c. ROTATE the potentiometer to change the state
of the LED. The green LED shall illuminate to
indicate that Power Close function is ON. The
red LED shall illuminate to indicate that the
Power Close function is OFF.
d. PRESS and RELEASE the "ENTER" pushbutton
to store the setting.
e. PRESS and HOLD the "ENTER" pushbutton for
three seconds. The operator shall exit
programming mode.
f. PRESS and HOLD the "ENTER" pushbutton for
three seconds. The operator shall exit
programming mode.