Linking the RF Pushbuttons

Linking the RF Pushbuttons
NOTE: Only ADAEZ transmitters can be linked to the
RF receiver of the operator.
Only one ADAEZ transmitter can be programmed at a
time. The procedure below can be repeated for up to
twelve ADAEZ transmitters. This RF pushbutton linking
method does not overwrite other RF controls previously
programmed into memory.
1. To link an RF switch with a door controller
PRESS and HOLD the "LEARN" pushbutton on the
controller until LEDs 1 through 4 flash green.
b. PUSH the RF pushbutton. LED "CLOSE
POSITION" shall flash green indicating that
11
Customizing Operator Settings (Optional)
NOTE: The parameters for OPEN and CLOSE TIME,
OPEN & POWER CLOSE FORCE, and HOLD-OPEN
TIME are preset to comply with ANSI standards for low-
energy operators but may be adjusted if approved by
the Authority Having Jurisdiction (AHJ).
Before attempting any changes to these settings, be
sure the Auto-Tune process has been successfully
completed.
1. PRESS and HOLD the "SELECT" and "ENTER"
pushbuttons for three seconds to enter
programming mode. LEDs 1 through 4 shall flash
green briefly.
• The "OPEN & CLOSE TIME" LED shall
illuminate.
3. PRESS and RELEASE the "SELECT" pushbutton
until the LED next to the setting to be modified
lights.
NOTE: The LED bar will indicate the previously set
value until the POTENTIOMETER is rotated.
4. With the desired LED illuminated, ROTATE the
thumbwheel to adjust the corresponding setting.
Refer to table 2 for approximate adjustment values.
NOTE: Verify adjustments using a stop watch and force
gauge.
the operator accepted this RF pushbutton.
c. REPEAT as necessary for additional ADAEZ
transmitters.
2. To remove all RF pushbuttons from memory,
PERFORM the following:
• PRESS and HOLD the "LEARN" pushbutton
on the controller,
• While holding down the "LEARN" pushbutton,
PRESS and RELEASE the "RESET"
pushbutton.
• RELEASE the "LEARN" pushbutton.
5. PRESS and RELEASE "ENTER" pushbutton to
store that value.
6. PRESS and HOLD the "ENTER" pushbutton for
three seconds. The operator shall exit
programming mode.
NOTE: The LED bar will indicate minimum and
maximum values as adjustments are made. Green
indications are within ANSI standards. Red indications
exceed ANSI standards.
OPEN & CLOSE TIME range is 2.5 to 9 seconds (open
and close times are calculated during the auto-setup
process).
OPEN & PWR CLOSE FORCE adjusts the force the
operator will apply in the open direction. If the optional
power close feature is turned on the power close force
will be adjustable using this setting.
HOLD OPEN time range is 1 to 30 seconds (default = 5
seconds).
EXECUTIVE MODE requires an activation to open the
door and a second activation to close the door.
7. TEST operator to confirm desired results. If
necessary, REPEAT adjustment.