5800 ADAEZ PRO
Installation and Operation Instructions
A
Attachments
3. ADAEZ Installation Schematics (Sheet 2 of 6)
ADAEZ PRO PLUS with Electric Lock and Access Control Panel - No Outside Button
System Description:
• A valid card presented to the reader will unlock
the door and initiate an automatic open cycle.
• ADAEZ Hardwired kit (p/n ADA1015P) is
REQUIRED.
• Inside pushbutton is always enabled.
Inside Wireless
Pushbutton
CARD READER
INSIDE
BUTTON
INSIDE BUTTON
PRESS & RELEASE
TO LEARN
HOLD TO ERASE
OPERATOR
SIGNAL
Figure 38
(ACCESS
CONTROL)
OUTSIDE
DOOR
BUTTON
OPERATOR
OUTSIDE BUTTON
PRESS & RELEASE
TO LEARN
HOLD TO ERASE
SIGNAL
DELAY
POWER IN
12 OR 24V
+
CH S
System Requirements:
• 1x ADA1028W Wireless Interface Module
• 1x ADA1012-2 – Rectangular Pushbutton with
RF transmitter
• Access Control BY OTHERS
ALARM
PANEL
FAIL SECURE
FAIL SAFE
45 of 50
LOCK
POWER
SUPPLY
700002-Rev N 09/18