Operator And Door Arm Installation Instructions - Pull Side Applications
Installing the Operator Mounting Bracket and Cover
For light duty or hollow-core doors with insufficient top
rail blocking, the provided through-bolts or sex nuts and
bolts must be used to securely attach the operator
mounting bracket.
1. If the door is aluminum and rivnuts must be
installed, refer to Figure 21 and PERFORM the
following:
a. Using a 25/64" drill, DRILL the mounting bracket
holes.
b. Using the provided rivnut tool, INSTALL the ¼-
20 steel rivnuts.
c. INSTALL and TIGHTEN the four(minimum) ¼-20
socket head capscrews (with supplied washers)
securing the operator mounting bracket.
2. If the door is wood, refer to Figure 21 and
PERFORM the following:
a. Using a 3/8" drill, DRILL the mounting bracket
pilot holes.
CAUTION
Figure 21
b. INSTALL and TIGHTEN the supplied through-
bolts, the four ¼-20 socket head capscrews
(with supplied washers) securing the operator
mounting bracket.
3. ADJUST the bracket so that there is a 5/8" (16mm)
space between the top of the bracket and the top
of the door.
4. TIGHTEN the socket head capscrews securing the
mounting bracket to the door.
5. Using a 7/16" box wrench or large adjustable
wrench, TIGHTEN the operator mounting pins into
the upper threaded holes in the mounting bracket.
6. INSTALL the operator mounting bracket cover over
the operator mounting bracket.