Assa Abloy 5800 ADAEZ PRO Installation And Operation Instructions Manual page 49

Table of Contents

Advertisement

®
5800 ADAEZ PRO
Installation and Operation Instructions
A
Attachments
3. ADAEZ Installation Schematics (Sheet 6 of 6)
ADAEZ PRO with 700 series Wave-to-Open activation switches AND Electric Lock
System Description:
• Operator is activated by Wave to Open Switch
• Wireless Interface Module unlocks electric lock
• Door initiates an automatic open cycle
WAVE TO
OPEN SWITCH
(BACK)
WAVE TO
OPEN SWITCH
(BACK)
Power +
Power -
N/O
C
N/C
W/ WHITE STRIPE
Figure 42
Power +
Power -
N/O
C
N/C
INSIDE
BUTTON
INSIDE BUTTON
PRESS & RELEASE
TO LEARN
HOLD TO ERASE
OPERATOR
SIGNAL
ADA1028W WIRELESS
INTERFACE MODULE
(NOT INCLUDED)
BLACK WIRE
BLACK WIRE
BLACK WIRE
ADA1015P HARDWIRE
KIT (INCLUDED)
System Requirements:
• ADAEZ with Wave to Open switches (p/n
5845xWTO)
• ADA1028W Wireless Interface Module
OUTSIDE
DOOR
BUTTON
OPERATOR
OUTSIDE BUTTON
PRESS & RELEASE
TO LEARN
HOLD TO ERASE
SIGNAL
DELAY
POWER IN
12 OR 24V
+
CH S
BLACK WIRE
W/ WHITE STRIPE
49 of 50
FAIL SECURE
LOCK
POWER
SUPPLY
FAIL SAFE
700002-Rev N 09/18