System Description

Features and Functions

Opening Time:
Following an activation signal, door moves from fully
closed to open check or 80°, whichever occurs first.
Opening time shall be in accordance with Table 1.
Hold-Open Time:
Hold open time shall be adjusted to no less than 5
seconds.
Closing Time:
Following hold-open time, door moves from fully open to
close check or 10°, whichever occurs first, according to
Table 1.
Close Check:
Close check shall occur in last 10° of closing and shall
not be less than 1.5 seconds.
Closing Force:
Door shall not close with a force greater than 15 lbs (6.8
kg) when measured at latch side of closing stile. For
ADAEZ series, closing force is adjustable to 8 lbs (3.6
kg).
Open and Power Close Force:
The operator shall be adjusted so that a stopped door
will apply a force in the opening direction of 15 lbs or
less. If the optional Power Close feature is enabled the
door shall be adjusted so that a stopped door will apply
a force of less than 15 lbs in the closing direction
Transmitter Range:
Transmitter has a range of 85' (26 m) from either side of
door.
Operation Upon Loss of Power:
Standard installations require no external power and
operation will not be affected during a power loss.
Typically a maximum of 2,500 cycles can be obtained
from a fully charged battery pack. Installations with a
power transformer will continue to function normally.
Operation Upon Obstruction:
If door meets an obstruction while opening, door will
remain under power for one second and then close
under spring force. If door meets an obstruction while
closing, door will maintain a closing force of 8 lbs (3.6
kg) or less.
Copyright © 2018, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights
reserved. Reproduction in whole or in part without the express written permission of ASSA
ABLOY Accessories and Door Controls Group, Inc. is prohibited.
Transmitter Learn Mode:
Transmitter Learn Mode programs transmitter to
operator. The system can learn up to twelve separate
transmitters. The system also has the ability to remove
all transmitters programmed into memory.
Auto-Setup Mode:
Auto-Setup Mode allows door to "learn" its fully open
and fully closed positions and adjusts the open time,
close time, open force, and hold open times to ensure
settings meet ANSI A156.19 Low Energy Door Operator
Code.
Option Features:
• Power Close: Door operator will apply a small
amount of power if door did not close in expected
close time to assist in closing door. Once door is
fully closed power close will turn off.
• Push and Go: Operator will power open door
when the door is manually moved in the open
direction.
• Dynamic Braking: Operator will brake door if
excessive door speed occurs resulting, for
example, from a wind load or an abusive open
condition.
• Latch Assist: Operator will apply a force in the
close direction for 1/2 second when the operator
receives an activate signal to assist an electric
strike in unlocking. When the door closes the
operator will apply a force in the close direction to
assist in latching the door.
Hold Open/Executive:
Operator provides an adjustable hold open time.
Controls on circuit board allow adjustment of door-
closing time delay from 1 second to 30 seconds. ANSI
156.19 requires the door hold open for a minimum of 5
seconds which is the default hold open setting. When
Executive mode is activated the door will open when it
receives an activate signal and remain open until it
receives a second activate signal.
NOTE: Power Close, Push and Go, Latch Assist, and
Executive Mode must only be enabled when unit is
powered using optional 24VDC Class 2 plug in
transformer.