Programming Instructions; Programming The Operator - Assa Abloy 5800 ADAEZ PRO Installation And Operation Instructions Manual

Table of Contents

Advertisement

®
5800 ADAEZ PRO
Installation and Operation Instructions
9

Programming Instructions

Programming the Operator

NOTE: The instructions programming the operator and
linking the RF pushbuttons are common regardless of
whether the door is a push or pull application. Refer to
Figure 35 during programing for Setup Board Layout.
1. Enter programming mode, Refer to Figure 35 and,
at the base of the setup board, PRESS and HOLD
both "SELECT" and "ENTER" pushbuttons until
LEDs 1 through 4 flash. The following shall occur:
• The operator shall enter program mode.
• The "CLOSE POSITION" LED shall illuminate
red and remain lit.
2. Program Door Closed position, with the door in the
closed position, PRESS and RELEASE the
"ENTER" pushbutton. The following shall occur:
• The "CLOSE POSITION" LED shall flash green
briefly.
• The "OPEN POSITION" LED shall illuminate red.
3. Program Door open position, with the door in the
fully open position, PRESS and RELEASE the
"ENTER" pushbutton. If the ENTER button is not
accessible with the door in the fully open position,
PRESS and RELEASE one of the activation
pushbuttons. The following shall occur:
• The "OPEN POSITION" LED shall flash green
briefly.
• The "AUTO SETUP" LED shall illuminate red.
4. Perform Auto-Setup, RETURN the door to the fully
closed position, and PRESS and RELEASE the
"ENTER" pushbutton. The following shall occur:
• The door shall rapidly open 30 to 45 degrees and
then close.
• The "AUTO SETUP" led shall illuminate green.
• The Operator will exit programming mode.
5. If further door adjustments are desired or optional
features will be enabled refer to Section 11, and
PERFORM adjustments.
6. To reset the controller, PERFORM the following:
PRESS and HOLD the "ENTER" button,
While holding down the "ENTER" button
PRESS and RELEASE the "RESET" button.
LEDs 1 through 4 shall flash green briefly
NOTE: Resetting the controller does not reset the RF
transmitters.
Setup Board Layout
OPEN & CLOSE TIME
OPEN & PWR CLOSE
FORCE
HOLD OPEN/
EXECUTIVE
1
2
PC
PG
OPTIONS
CLOSE
OPEN
POSITION
POSITION
LEARN
SELECT
Figure 35
34 of 50
LEDs 1-4
ADJUSTMENT
3
4
INDICATOR
LA
DB
OPTIONS:
POWER CLOSE
PUSH & GO
DYNAMIC BRAKING
LATCH ASSIST
AUTO
SETUP
TUNING
POTENTIOMETER
RESET
ENTER