Push Side Template; Push Side Installation - Assa Abloy Norton 7200 Series Installation And Instruction Manual

Multi-point hold open
Table of Contents

Advertisement

Double Lever Arm (Push Side)
Use of an auxiliary door stop, by
others, is required for these applications.
RH - Right Hand
LHR - Left Hand Reverse
1
Prepare Frame
Drill #7; Tap 1/4-20 UNC
4
(101.6)
A
C
Hinge or Pivot
2
Closer Mounting
Install two screws in
the key slot locations
leaving 1/8" gap
between screw head
and frame face as
shown (a).
Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
19-3/4
(501.7)
11-1/4
(285.8)
5/16
(7.9)
B
Left hand door shown, right hand opposite.
All dimensions shown in inches (mm).
C
Ceiling Line
3-1/2
Min
(89)
2
Min
(51)
Hinge
Edge
Of
Door
11/16
(17.5)
1-5/8
(41.3)
1-3/4
(44.5)
DOOR OPENING
ANGLE
To 100°
100° to 180°
a
2
LH - Left Hand
RHR - Right Hand Reverse
7/8
(22.2)
7/8
DIA THRU
(22.2)
For Concealed
Wiring Only
Frame Rabbet
Top of
Door
1-3/4
(44.5)
Frame
Soffit
Dim "A"
Inches (mm)
5-7/8
149.2
13-3/8
79.4
3-1/8
10-5/8
1/8"
80-9372-0100-020 (02-14)
ASSA ABLOY
Dim "B"
Inches (mm)
339.7
269.9

Advertisement