Responding to Error Messages

This section describes the error messages that may appear on VPanel and how to take action to remedy the problem. If the
action described here does not correct the problem, if an error message not described here appears, or if you need to replace
a part or an included item such as the collet, contact your authorized Roland DG Corporation dealer.
Error number
Message
1000-****
The % limit switch
is not found.
(% may be "X,"
"Y," "Z," or "A.")
1006-****
T h e % a x i s
p o s i t i o n h a s
been shifted.
(% may be "X,"
"Y," "Z," or "A.")
1017-0000
T h e c o v e r i s
open.
101D-0000
The milling bur
cannot be re-
leased.
Situation/error cause
Operation may be inhibited
by milling waste or an ob-
struction.
The motor position may
have been lost.
The milling conditions may
be excessively strict.
The front cover was opened
during spindle rotation.
(For safety, the machine
comes to an emergency
stop if the front cover is
opened while the spindle
is rotating.)
The returning of the milling
bur failed. The cause may
be dirt inside the collet or
on the ATC magazine or
damage or deformation of
the collet.
The collet and milling bur
are affixed together and
cannot be separated. The
cause may be dirt inside
the collet or damage or
deformation of the collet.
There is a possibility that
the spindle unit is defec-
tive.
Action
1. Turn off the power.
2. Remove any objects blocking operation of the
machine and any accumulated milling waste.
3. Turn on the power, and then restart operation.
1. Remove any objects blocking operation of the
machine and any accumulated milling waste.
2. Press and hold the operation button on the built-
in panel. This will clear the error.
1. Review the CAM settings and the shape specified
in the milling data.
2. Press and hold the operation button on the built-
in panel. This will clear the error.
1. Turn off the power.
2. Close the front cover.
3. Turn on the power.
1. Follow the messages displayed in VPanel to forc-
ibly release the milling bur.
If the bur is difficult to remove because the connec-
tion portion is stuck, shake the milling bur to the
left and right while pulling downward.
2. Perform collet maintenance. Carefully clean the
inside of the collet.
P. 23 "STEP 0: Spindle Run-In (Short)"
3. Clean the ATC magazine.
P. 34 "Cleaning after Milling Finishes"
If the error occurs again even after you perform
the above operations, the collet may be deformed.
In this case, replace the collet. Perform automatic
correction after the replacement.
P. 39 "Milling Machine Correction"
If the error occurs again even after you replace the
collet, replace the spindle unit. After you replace
the spindle unit, correct the milling machine.
P. 49 "Replacing the Spindle Unit"