Milling Quality Problems; The Milling Results Are Not Attractive; There Is A Line Of Level Difference In The Milling Results; The Dimensions Of The Milling Results Do Not Match - Roland DWX-4W User Manual

Hide thumbs Also See for DWX-4W:
Table of Contents

Advertisement

Milling Quality Problems

The Milling Results Are Not Attractive

Is the workpiece firmly secured in place?
Is the milling bur worn?
Are the milling conditions too strict?
Is the machine out of correction?

There Is a Line of Level Difference in the Milling Results

Is the machine out of correction?
Are the CAM milling conditions correct?

The Dimensions of the Milling Results Do Not Match

Does the milling bur diameter match the
CAM settings?
Does the set temperature of the sintering
program match the workpiece?
Check the mounting condition of the workpiece. Fasten the
workpiece in place securely so that it will not slip out of place
or come loose because of milling bur pressure or vibration
during milling.
If the same milling bur is used for milling for a long period
of time, it will become worn and affect milling results. Try
replacing the milling bur with a new one. The work time of
the milling bur can also be managed in VPanel.
Strict milling conditions may affect milling results. Review the
CAM milling conditions.
The origin point may become out of position due to
prolonged use or relocating the machine, which can result
in a line of level difference. Perform automatic correction. If
expected results cannot be obtained even after performing
automatic correction, perform manual correction. With
manual correction, changing the Y value under Origin point
may improve the situation.
The origin point may become out of position due to
prolonged use or relocating the machine, which can result
in a line of level difference. Perform automatic correction. If
expected results cannot be obtained even after performing
automatic correction, perform manual correction. With
manual correction, changing the Y value under Origin point
may improve the situation.
Incorrect CAM milling settings may lead to line of level
differences. Review the CAM milling conditions.
Check the CAM settings.
Check the set temperature of the sintering program to see if it
matches the workpiece of the manufacturer used.
P. 24
P. 12
-
P. 39
P. 11
P. 39
P. 11
-
-
-
4. Troubleshooting
69