Roland DWX-4W User Manual page 30

Hide thumbs Also See for DWX-4W:
Table of Contents

Advertisement

Following Daily Operations
2.
Clean the inside of the spindle and the collet.
Collet
Collet
replacement jig
Collet tap
30
2. Milling
Clean the inside of the spindle (where
contact with the collet is made) with
the taper cleaner.
Rotate the taper cleaner left and right as if you are
brushing the inner portion of the spindle.
Wipe the outer portion of the collet with
a clean, dry cloth.
Do not hold the tapered portion tightly. This part
being deformed may result in malfunctions.
Clean the inner portion of the collet
with the collet brush.
Rotate the collet brush left and right as if you are
brushing the inner portion of the collet.
Lightly apply grease to the tapered
portion on the outside of the collet.
A thin application is sufficient. Do not apply
excessively.
Assemble the collet, collet replacement
jig, and collet tap as shown in the figure,
and then insert this assembly into the
spindle.