Machine Problems

Collet Maintenance Cannot Continue Due to an Error Occurring

Is the message "1039-0000 The pressure
of the compressed air is too high or low."
displayed on VPanel?
Is anything caught on the spindle unit or
rotary axis unit?

Water Is Leaking from the Front Cover

Is the waterproof plate attached properly?
68
4. Troubleshooting
If you take too long to perform the collet maintenance, the
supply of compressed air will become insufficient, and it will
no longer be possible to continue the collet maintenance.
Follow the procedure below to perform the maintenance
again.
1. Turn off the machine's power.
2. Supply the appropriate amount of compressed air.
P. 17 "Preparing Compressed Air (Setting the Regulator)"
3. Open the front cover.
4. Turn on the power.
5. Click [OK] in the message window displayed on VPanel to
clear the message.
6. In VPanel, click the [Maintenance] tab, and then click
[Emergency release].
7. Click [OK] in the message window displayed.
8. The collet is open, so use the collet replacement jig and the
collet tap to close the collet.
9. Close the front cover. When the machine stops operating
and the status light turns on in blue, the machine is in the
ready status.
10. Perform the collet maintenance again.
Check whether something has become caught and is
impeding initialization.
If the waterproof plate is not attached properly, water may
leak. Check the installation of the waterproof plate.
For information on how to attach the waterproof plate, refer
to the "Setup Guide" or the page listed to the right ("Cleaning
the Waterproof Plate").
-
-