Extended Periods of Non-Use / Moving the Machine

Draining the Coolant Lines

Drain the fluid collected in the coolant lines running through the machine.
Situations Requiring This Work
 When there are no plans to use the machine for 1 week or longer (or when the machine has not been used for 1 week
or longer)
 Before moving the machine (especially when there is a risk of coolant spillage)
Required Tools
Commercially
available item
Tray
Draining
Procedure
If a workpiece or a milling bur is mounted on the machine, remove it.
Remove the coolant tank and discard the coolant.
Proceed to the next step without returning the coolant tank to its original position.
P. 18 "Filling the Coolant Tank/Replacing the Coolant"
Show VPanel.
P. 5 "Displaying VPanel"
Do not remove the detection pin.
Place the tray with the coolant tank
inside the bottom cover in the stored
position.
Important
Because some water may drip when draining
the pathways, keep the tray in place until the
coolant tank is returned to its original position.