Chapter 8 Troubleshooting

Troubleshooting the Power Subsystem

Check the following to help isolate a problem in the power subsystem. In the normally configured
SCE 1000 platform with redundant power supply units, it is unlikely that the device will not start at all.
However, at startup it should be verified that both power supply units are operational, and therefore the
following steps should be followed if one of the Power LEDs on the front panel remains unlit when the
SCE 1000 platform is powered up.
Note
If the system powers off due to an environmental shutdown, wait at least one minute before manually
rebooting the system, or it will pause indefinitely.
Table 8-4
Symptom
Power LED on the front panel
and LEDs on the power supply
unit are not lit, or do not remain
lit continuously.
OL-26790-01
If the banner is displayed, but the Status LED is flashing orange, indicating a warning state, check
the user log:
At the prompt, type: more user log
If any of the following warning messages appear, turn the SCE 1000 platform off and call technical
support.
"voltage problem"
"fans problem"
"abnormal raise in interior temperature"
If the following warning message appears, delete unneeded files from the disk.
"insufficient disk space"
Troubleshooting the Power Subsystem
Possible Cause
Power cable not fully seated at
system.
Power cable not fully seated at
source.
Power source is faulty.
Cisco SCE 1000 2xGBE Installation and Configuration Guide
Problem Solving Using a Subsystems Approach
Possible Solution
Turn the power switch to the off
position and reseat the power
cable in the system.
Turn the switch to the off
position and reseat the power
cable at the power source.
Turn the switch to the off
position, connect the power
cable to another power source, if
available, and turn the switch
back on.
8-7

Advertisement

Table of Contents
loading

Table of Contents