Chapter 4 Installation and Maintenance
Note that the power to the relevant power supply unit should be off, not necessarily all power to the
Note
SCE 1000 platform. One DC-input power supply can be running when the other power supply is being
removed or replaced.
Step 1
Place the on/off switch on the DC-input power supply in the OFF position.
Make sure that power is removed from the DC circuit by turning off the circuit breaker or switch
Step 2
providing power to the DC-input power supply.
Step 3
Observe that the corresponding Power LED on the front panel turns off.
Remove the screw from one DC power line input lead receptacle and pull the lead from the connector.
Step 4
Repeat this step for the remaining lead.

What to Do Next

This completes the procedure for powering down an DC-input power supply unit on a SCE 1000
platform. Proceed to

How to Remove the Power Supply Unit

To remove the AC-input or DC-input power supply unit from the SCE 1000 platform, complete the
following steps:
Step 1
Using a 1/4-inch flat-blade screwdriver, loosen the captive installation screw on the corner of the
faceplate of the power supply.
Step 2
Grasp the power supply handle and pull the power supply from the router.
OL-26790-01
How to Remove the Power Supply Unit, page
Cisco SCE 1000 2xGBE Installation and Configuration Guide
How to Remove the Power Supply Unit
4-19.