Single or multiple module mounting kit (see
1 ea. .312 x 2.5 x 3.62 x 1.5 U-bolt
2 ea. 5/16" SST split washer
2 ea. 5/16" SST flat washer
2 ea. 5/16-18 SST lock nut
Sample conditioning module(s) and hardware (see

3.13.2 Mounting Kits

Both the sample conditioning module mounting brackets are installed identically.
The single module bracket holds a single stream sample conditioning module,
while the multiple module bracket holds up to three sample conditioning modules.
A
A
B
B
2" Pipe
SINGLE MODULE BRACKET

3.13.3 Instructions

1) On the sample conditioning module, align the mounting holes to the
2) Place the split washer and then the flat washer on the bolt. Screw the nut onto
the end of the bolt until finger tight. Repeat for the second mounting bolt. Tighten
both nuts.
3) Repeat for all additional modules.
4) Straddle the mounting pipe with the U-bolt and insert the threaded ends through
the holes located in the mounting bracket so that the bracket back fits flat against
the pipe, and the module mounting lip sets away from the pipe.
5) Place the flat washer, then a split washer on the end of the U-bolt. Screw the nut
onto the end of the bolt and finger tighten.
6) Repeat step 4 for the other side of the U-bolt.
7) Move the bracket into position underneath the NGC, being careful to allow
clearance for the sample conditioning module(s).
Page 3–22
A
A
MULTIPLE MODULE BRACKET

Figure 3-23 Sample System Mounting Kits

When installing module bracket inside of the ENC82S small
environmental enclosure, mounting bracket must be installed
upside down to allow for required space. Otherwise, module
bracket installed inside of the ENC82L large environmental
enclosure should be oriented as shown in
corresponding holes in the bracket. See the caution note above regarding
orientation of the mounting bracket. Insert the bolt through the hole in the
bracket, from front to back through the mounting hole in the module.
Figure
3-23)
Figure 3-23
VIEW A-A
VIEW B-B
U-Bolt
2 EA. 5/16-18 SST LOCKING HEX NUT
2 EA. 5/16" SST FLAT WASHER
2 EA. 5/16" SST SPLIT LOCK WASHER
Figure
and
Figure
3-24)
3-24.