Material Required; Instructions; Large Free-Standing Environmental Enclosure Installation; Materials - ABB NGC8206 User Manual

Chromatograph
Hide thumbs Also See for NGC8206:
Table of Contents

Advertisement

3.4.1

Material required

or
3.4.2

Instructions

1) Select a location to install the mounting pipe that allows easy access and is
2) Install a mounting pipe, and ensure the pipe is vertically aligned.
3) Screw 2 inch pipe coupling onto the top of the mounting pipe.
4) Screw optional mounting flange pipe into the top of the pipe coupling.

3.5 Large Free-standing Environmental Enclosure Installation

The following steps will typically require two people.
3.5.1

Materials

4 ea. ½-13 x 1 ¼ SST bolt
4 ea. ½ SST flat washer
4 ea. ½" SST split washer
1 ea. stand
3.5.2

Installation

1) The stand is symmetrical, so the top and bottom are identical. Locate the
2) Set the enclosure on top of the stand, oriented so that the stand brace is
horizontal with the front of the enclosure (see
2101510 Rev. AG
One 2 inch pipe with flange
One 2 inch pipe coupling
One 2 inch mounting pipe (installed). Length dependent upon final overall
NGC desired height.
Optional equipment may be ordered from Totalflow.
close to the sample probe. Lines should be as short as possible.
Continue to the NGC Installation instructions.
Method of installation must be consistent with customer's
company policy.
If the installation includes a free-standing environmental
enclosure, follow these instructions; otherwise, skip to the
next section.
stand base on a flat, stable, surface.
Figure
3-5).
Page 3–7