Navigator 550
sodium wet-section
These procedures must be carried out by a trained
technician.
Tools required
• Pozidrive screwdriver
• Slot-head terminal screwdriver
• Anti-static strap.
Introduction
Spares replacement procedures
Measurement made easy
2
For more information
Further information is available from:
www.abb.com/analytical
or by scanning these codes:
Sales
Service

Advertisement

loading

Summary of Contents for ABB Navigator 550 Sodium wet-section

  • Page 1 For more information Navigator 550 sodium wet-section These procedures must be carried out by a trained Further information is available from: technician. www.abb.com/analytical Tools required or by scanning these codes: • Pozidrive screwdriver • Slot-head terminal screwdriver • Anti-static strap.
  • Page 2: Replacement Procedures

    3 Safety 3 Safety 4 Replacement procedures Warning. Modbus cable assembly – see Section 4.5, page 5 These procedures must be carried out by a trained technician. CHEMICAL PCB housing seals, PCB cover and PCB –  Ensure personal protective equipment (PPE) such as see Section 4.1, page 3 are worn during any gloves...
  • Page 3 4 Replacement procedures 4.1 Replacing the PCB housing seals, PCB cover and PCB Entry Cable Color Terminal Description 24 V Part numbers: Serial (Modbus) – refer to Black  PCB housing seals: AW501 051 Operating Instructions Green Data +ve (OI/ASO550-EN) ...
  • Page 4 4 Replacement procedures 4.3 Replacing the constant-head assembly, pressure switch 4.4 Replacing the solenoid valve assembly and assembly and pressure switch cable solenoid valve cable(s) Part numbers: Part numbers:  Constant-head assembly: AW501 061  Sodium multi-stream solenoid valve: AW501 053 ...
  • Page 5 4 Replacement procedures 4.5 Replacing the Modbus cable assembly Modbus cable part numbers:  AW501 090 / 1.5 m (4.9 ft.)  AW501 091 / 5 m (16.4 ft.)  AW501 092 / 10 m (32.8 ft.)  AW501 093 / 20 m (65.6 ft.) Referring to Section 4.2, page 3: 1.
  • Page 6 Notes Notes INF13/115–EN Rev. B | Navigator 550 | Sodium wet-section| Spares replacement procedures...
  • Page 7 Notes Navigator 550 | Sodium wet-section | Spares replacement procedures | INF13/115–EN Rev. B...
  • Page 8 We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.