Block Programming Instructions
Example
0000
00
Flags
In the following example, B will be executed after the execution of A and after
7,000 counts of CIO 000100 while CIO 000000 is ON.
(250)
BPRG
00
A
CNTW<014>
B
BEND<001>
ER (A50003):
SV data is not BCD.
Indirectly addressed DM word is non-existent. (Content of
*DM word is not BCD, or the DM area boundary has been
exceeded.)
Address Instruction
000000
LD
000001
BPRG(250)
A
0005
#7000
000200
CNTW<014>
000100
B
000300
BEND<001>
Section 5-38
Operands
000000
00
0005
#
7000
000100
449