Multiple Bit Set/Reset: Seta(047)/Rsta(048) - Omron SYSMAC CV Series Operation Manual

Ladder diagrams
Hide thumbs Also See for SYSMAC CV Series:
Table of Contents

Advertisement

Bit Control Instructions
Precautions
Flags
Example
0000
00
0500
00
0000
01

5-7-4 MULTIPLE BIT SET/RESET: SETA(047)/RSTA(048)

Ladder Symbol
(047)
SETA D N
(048)
RSTA D N
Variations
SETA(047), RSTA(048)
Description
130
The status of operand bits for SET(016) and RSET (017) programmed between
IL(002) and ILC(003) or JMP(004) and JME(005) will not change when the inter-
lock or jump condition is met (i.e., when IL(002) or JMP(004) is executed with an
OFF execution condition).
Note: Refer to page 115 for general precautions on operand data areas.
There are no flags affected by these instructions.
In the example below, CIO 050000 is turned ON whenever CIO 000000 is ON,
and turned OFF whenever CIO 000001 is ON.
(016)
SET
(017)
RSET
Operand Data Area
D: Rightmost word for set
N
1
2
N
: Beginning bit
1
N
: Number of bits
N
1
2
2
When the execution condition is OFF, SETA(047) is not executed. When the
execution condition is ON, SETA(047) turns ON a designated number of bits,
beginning from the designated bit of the designated word, and continuing to the
left (more-significant bits). All other bits are left unchanged.
Unchanged
When the execution condition is OFF, RSTA(048) is not executed. When the
execution condition is ON, RSTA(048) turns OFF a designated number of bits,
beginning from the designated bit of the designated word, and continuing to the
left (more-significant bits). All other bits are left unchanged.
Unchanged
050000
0050
00
050000
CIO, G, A
CIO, G, A, T, C, #, DM, DR, IR
CIO, G, A, T, C, #, DM, DR, IR
Number of bits
Number of bits
Section 5-7
Address Instruction
Operands
00000
LD
000000
00001
SET(016)
050000
00002
LD
050000
00003
OUT
005000
00004
LD
000001
00005
RSET(017)
050000
(CVM1 V2)
Rightmost word
Unchanged
Beginning bit
Rightmost word
Unchanged
Beginning bit

Hide quick links: