Block Set: Bset(041) - Omron SYSMAC CV Series Operation Manual

Ladder diagrams
Hide thumbs Also See for SYSMAC CV Series:
Table of Contents

Advertisement

Data Movement Instructions

5-15-11 BLOCK SET: BSET(041)

Ladder Symbol
(041)
BSET
S
Variations
j BSET(041)
Description
Precautions
Flags
198
St
E
When the execution condition is OFF, BSET(041) is not executed. When the ex-
ecution condition is ON, BSET(041) copies the content of S to all words from St
through E.
S
3 4 5
2
BSET(041) can be used to change timer/counter PV. BSET(041) can also be
used to clear sections of a data area, i.e., the DM area, to prepare for executing
other instructions.
St must be less than or equal to E. St and E must be in the same data area.
The BSET(041) operation might not be completed if a power interruption occurs
during execution of the instruction.
Note Refer to page 115 for general precautions on operand data areas.
Content of *DM word is not BCD when set for BCD.
ER (A50003):
St is greater than E.
Operand Data Areas
S: Source word
CIO, G, A, T, C, #, DM, DR, IR
St: Starting word
CIO, G, A, T, C, DM
E: End word
CIO, G, A, T, C, DM
St
3 4 5
2
St+1
3 4 5
2
St+2
3 4 5
2
E
3 4 5
2
Section 5-15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cv2000Cvm1Cv500Cv1000

Table of Contents