6.14.7 Commissioning an analog axis
Temporary
input values
1060
Enter the following temporary input values when you begin
MP
Temporary
input value
MP1030.x
0.01
MP1090.x
1
MP1092
<Maximum rapid
traverse>
MP1110.x
2.0
MP1140.x
10
MP1410.x
0.5
MP1420.x
2
MP1510.x
1
MP1710.x
50
MP1720.x
50
MP1810.x
1
MP1820.x
1
MP1830.x
100
Meaning
Positioning window
Maximum permissible jerk on the tool path
Feed rate threshold from which MP1090.1
becomes effective
Standstill monitoring
Movement monitoring
Position monitoring in operation with
velocity feedforward control (erasable)
Position monitoring in operation with
velocity feedforward control
(emergency stop)
k
factor for velocity feedforward control
v
Position monitoring in operation with
following error (erasable)
Position monitoring in operation with
following error (EMERGENCY STOP)
k
factor for control with following error
v
Multiplier for the k
v
Characteristic curve kink point
HEIDENHAIN Technical Manual iTNC 530 HSCI
factor