HP 64700 Series User Manual page 41

64000-ux case solutions for microprocessors, softkey interface
Hide thumbs Also See for 64700 Series:
Table of Contents

Advertisement

Trace List
Label:
Address
Data
Base:
hex
hex
after
000406
2241
pstore
00040A
6100
pstore
000438
6100
+003
000530
3737
pstore
00040A
6100
pstore
000444
6100
+006
000545
7070
pstore
00040A
6100
pstore
000432
6100
+009
000537
8E8E
pstore
00040A
6100
pstore
00043E
6100
+012
000570
3434
pstore
00040A
6100
pstore
000432
6100
STATUS:
M68000--Running user program
trace
after AGAIN only
run
trace
step
Offset=0
More data off screen (ctrl-F, ctrl-G)
Opcode or Status
mnemonic
MOVEA.L D1,A1
BSR.W********
BSR.W********
37
supr data wr byte
BSR.W********
BSR.W********
70
supr data wr byte
BSR.W********
BSR.W********
8E
supr data wr byte
BSR.W********
BSR.W********
34
supr data wr byte
BSR.W********
BSR.W********
Emulation trace complete______...R....
range RESULTS thru RESULTS+0ffh prestore
display
modify
The prestore state immediately preceding each write state shows
the address of the caller.
The analyzer uses the same resource to save prestore states as it
does to save count tags. Consequently, no count appears for
prestore states. Time counts are relative to the previous normal
storage state.
States which satisfy the prestore qualifier and the storage qualifier
at the same time are stored as normal states.
time count
relative
2.6
26.6
30.4
28.0
29.2
data 6100h
break
end
---ETC--
Getting Started 2-17
uS
uS
uS
uS
uS

Advertisement

Table of Contents
loading

Table of Contents