9-88 Timing: Commands
nanoseconds, microseconds, or milliseconds,
respectively.
< DOT>
This prompts you to enter the literal "." to
designate a specific bit number of a label.
greater_than
This option specifies a duration a pattern
should last for the specified signals. If the
pattern is detected but does not last at least
the specified amount of time, the trigger
condition is not met.
less_than
This option specifies a duration a pattern
should not exceed for the specified signals. If
the pattern is detected an lasted longer than
the specified amount of time, the trigger
condition is not met.
modify
This option returns the current trigger
command to the command line for editing.
pattern
This option specifies the trigger condition
will be a signal pattern.
on
This option specifies the trigger point of a
measurement or set of measurements.
< PATT>
This prompts you to enter a pattern of
signals. The pattern is a numerical value, the
significance of which is dependent on the
number of signals being tested. Refer to the
section on Entering Numerical Values in this
manual for options on entering patterns.
position_is
This option specifies the positioning of the
trigger in trace memory. If the trigger is
positioned at the start of trace memory, the
majority of samples will be after the trigger;
if it is positioned at the end of trace memory,
the majority of samples will be before the
trigger; and if it is positioned at the center,

Advertisement