10. Removal procedures of work equipment
pump
Remove work equipment pump by pulling it
toward the front according to the following pro-
cedures.
1)
Shift the pump closer to the front end until
wire rope [2] almost makes contact with
the counterweight.
2)
Pull chain block [1] up and loosen wire
rope [2].
3)
Disconnect wire rope [2] from the work
equipment pump.
10
50 Disassembly and assembly
4)
Install wire rope [2] to the work equipment
pump from outside the counterweight.
a Apply rubber plates or cloth [3] to the
counterweight to prevent it from being
damaged by wire rope.
5)
Lower chain block [1] and hold the work
equipment pump in level state.
6)
Shift the pump closer to the front end until
chain block [1] almost makes contact with
the counterweight.
7)
Lower the chain block [1] and loosen
chain block [1].