30 Testing and adjusting
4.
Contents of setting of each maintenance item
After selecting each maintenance item, if the
screen is displayed, set the item with the func-
tion switches.
Initial value: Maintenance interval set in
q
machine monitor (Recommended by man-
ufacturer and not changeable).
Set value: Maintenance interval which can
q
be set freely. Maintenance functions in
operator mode operate on basis of this set
time (which is increased or decreased by
50 hours).
ON: Maintenance function of this item is
q
set effective in operator mode.
OFF: Maintenance function of this item is
q
set ineffective in operator mode.
[F3]: Select Reduce set value (Upper) or
q
OFF (Lower).
[F4]: Select Increase set value (Upper) or
q
ON (Lower).
[F5]: Cancel setting before confirmation
q
and return to Maintenance mode
change screen.
[F6]: Confirm setting of upper or lower line.
q
a After the setting of the upper and lower
lines is confirmed with [F6] and the screen
c h a n g e s t o t h e M a i n t e n a n c e m o d e
change screen with [F5], the setting is
effective.
a If the set value of an item set to "ON" is
changed after 1 or more operating hours
since the start of setting, the change is
recognized as a resetting operation.
PC138US, USLC-8
5.
Function of initializing all items
After selecting "All Default Value", if the screen
is displayed, set with the function switches.
If this operation is executed, the set val-
q
ues of all the maintenance items are ini-
tialized.
[F5]: Return to Maintenance mode change
q
screen
[F6]: Execute initialization
q
a A while after [F6] is pressed, the initializa-
tion completion screen is displayed. Then,
if the "Maintenance Mode Change" screen
is displayed, initialization is completed.
SEN02459-00