30 Testing and adjusting
4.
Executing monitoring
After the "Executing monitoring screen" is dis-
played, perform the necessary operation of the
machine and check the monitoring information.
a Monitoring information is indicated by
value, ON/OFF, or special display.
a The unit of display can be set to SI unit,
metric unit, or inch unit with the Initializa-
tion function in the service mode.
5.
Holding monitoring information
The monitoring information can be held and
reset with the function switches.
[F3]: Reset holding
q
[F4]: Hold information (displayed data)
q
[F5]: Return to monitoring selection menu
q
screen
PC138US, USLC-8
6.
Changing machine setting mode
To change the setting of the working mode,
travel speed, or auto-deceleration during moni-
toring, operate the corresponding switch under
the current condition, and the mode setting
screen is displayed.
While this screen is displayed, if the corre-
sponding switch is operated further, the corre-
sponding mode is changed.
a After finishing changing the setting, press
[F6] to return to the monitoring information
screen.
a If the setting is changed during monitoring,
the new setting is held even after the
screen returns to the ordinary screen after
monitoring is finished.
SEN02459-00
21