6.11 NUMeric Group

The command in this group deal with numeric data output.
There are no front panel keys that correspond to the commands in this group.
The commands in the DISPlay group are used to make the same settings and queries as the FUNCTION and
ELEMENT keys on the front panel.
:NUMeric?
Function
Queries all numeric data output settings.
Syntax
:NUMeric?
:NUMeric:FORMat
Function
Sets or queries the numeric data format.
Syntax
:NUMeric:FORMat {ASCii|FLOat}
:NUMeric:FORMat?
Example
:NUMERIC:FORMAT ASCII
:NUMERIC:FORMAT?
-> :NUMERIC:FORMAT ASCII
Description • The format of the numeric data that is output
varies depending on how this command is set.
The different formats are explained below.
(1) ASCii
Physical values are output in the <NR3>
format.(Only the elapsed integration time—
TIME—is output in <NR1> format.)
The data items are separated by commas.
(2) FLOat
A header (for example, "#240" or "#3208") is
added in front of each numeric data block.
A physical value in IEEE single-precision
floating point (4-byte) format follows the
header.
The byte order of the data of each item is MSB
First.
• For the formats of each individual numeric data
item, see "Numeric Data Formats" at the end of
this group of commands (page 6-25).
:NUMeric:NORMal?
Function
Queries all numeric data output settings.
Syntax
:NUMeric:NORMal?
Description The number of numeric data items output by :
NUMeric[:NORMal]:ITEM<x> is determined by :
NUMeric[:NORMal]NUMber.
IM WT310E-17EN
:NUMeric[:NORMal]:VALue?
Function
Queries the numeric data.
Syntax
:NUMeric[:NORMal]:VALue? {<NRf>}
<NRf> = 1 to 255 (item number)
• When <NRf> is specified
Example
:NUMERIC:NORMAL:VALUE? 1
-> 103.79E+00
• When <NRf> is omitted
:NUMERIC:NORMAL:VALUE?
-> 103.79E+00,1.0143E+00,105.27E+0
0,.. (omitted) ..,50.001E+00
• When :NUMeric:FORMat is set to {FLOat}
:NUMERIC:NORMAL:VALUE?
-> #N (N-digit byte number)(data byte
sequence)
Description • If <NRf> is specified, only the numeric data for
the specified item is output.
• If <NRf> is omitted, the numeric data items
from 1 to the number specified by the :
NUMeric[:NORMal]:NUMber command are
output in order.
• For the formats of each individual numeric data
output item, see "Numeric Data Formats" at the
end of this group of commands (page 6-25).
:NUMeric[:NORMal]:NUMber
Function
Sets or queries the number of numeric data items
that are transmitted by the :NUMeric[:NORMal]:
VALue? command.
Syntax
:NUMeric[:NORMal]:NUMber {<NRf>|ALL}
:NUMeric[:NORMal]:NUMber?
<NRf> = 1 to 255(ALL)
Example
:NUMERIC:NORMAL:NUMBER 10
:NUMERIC:NORMAL:NUMBER
-> :NUMERIC:NORMAL:NUMBER 10
Description • If the parameter is omitted from the :NUMeric[:
NORMal]:VALue? command, the numeric data
items from 1 to the specified value are output
in order.
• By default, the number of numeric data items is
set to 10.
1
2
3
4
5
6
7
8
9
App
Index
6-19