6.7 INPut Group
Description In the parameters, list the external current sensor
ranges that you want to enable. To enable all the
ranges, specify the parameter "ALL."
[:INPut]:CURRent:EXTSensor:POJump
Function
Sets or queries the jump destination range that is
used when a current peak over-range occurs.
Syntax
[:INPut]:CURRent:EXTSensor:POJump
{OFF|< Voltage >}
[:INPut]:CURRent:EXTSensor:POJump?
OFF = No jump destination current range
<Voltage> = See ( :INPut:CURRent:
RANGe ).
Example
:INPUT:CURRENT:EXTSENSOR:POJUMP 2V
:INPUT:CURRENT:EXTSENSOR:POJUMP?
-> :INPUT:CURRENT:EXTSENSOR:POJUMP
2.00E+00
[:INPut]:CURRent:SRATio?
Function
Queries the external current sensor conversion
ratios of all elements.
Syntax
[:INPut]:CURRent:SRATio?
Description This command is only valid on models with the
external current sensor input (/EX1 or /EX2)
option.
[:INPut]:CURRent:SRATio[:ALL]
Function
Collectively sets the external current sensor
conversion ratios of all elements.
Syntax
[:INPut]:CURRent:SRATio[:ALL]
{<NRf>}
<NRf> = 0.001 to 9999.
Example
:INPUT:CURRENT:SRATIO:ALL 10
[:INPut]:CURRent:SRATio:ELEMent<x>
Function
Sets or queries the external current sensor
conversion ratio of the specified element.
Syntax
[:INPut]:CURRent:SRATio:ELEMent<x>
{<NRf>}
[:INPut]:CURRent:SRATio:ELEMent<x>?
<x> = 1 to 3 (element)
<NRf> = 0.001 to 9999.
Example
:INPUT:CURRENT:SRATIO:ELEMENT1 10
:INPUT:CURRENT:SRATIO:ELEMENT1?
-> :INPUT:CURRENT:SRATIO:ELEMENT1
10.00
[:INPut]:RCONfig
Function
Sets or queries the on/off state of the range
configuration (valid range selection) feature.
Syntax
[:INPut]:RCONfig {<Boolean>}
[:INPut]:RCONfig?
Example
:INPUT:RCONFIG OFF
:INPUT:RCONFIG? -> :INPUT:RCONFIG 0
6-14
Description The following commands are enabled only when
this command is set to ON. Measurement range
can be skipped.
:INPut:VOLTage:CONFig
:INPut:VOLTage:POJump
:INPut:CURRent:CONFig
:INPut:CURRent:POJump
:INPut:CURRent:EXTSensor:CONFig
:INPut:CURRent:EXTSensor:POJump
[:INPut]:SCALing?
Function
Queries all scaling settings.
Syntax
[:INPut]:SCALing?
[:INPut]:SCALing[:STATe]
Function
Sets or queries the scaling on/off state.
Syntax
[:INPut]:SCALing[:STATe] {<Boolean>}
[:INPut]:SCALing:STATe?
Example
:INPUT:SCALING:STATE OFF
:INPUT:SCALING:STATE?
-> :INPUT:SCALING:STATE 0
[:INPut]:SCALing:{VT|CT|SFACtor}?
Function
Queries the VT ratios, CT ratios, or power
coefficients of all elements.
Syntax
[:INPut]:SCALing:{VT|CT|SFACtor}?
[:INPut]:SCALing:{VT|CT|SFACtor}
[:ALL]
Function
Collectively sets the VT ratio, CT ratio, or power
coefficient of all elements.
Syntax
[:INPut]:SCALing:{VT|CT|SFACtor}
[:ALL] {<NRf>}
<NRf> = 0.001 to 9999.
Example
:INPUT:SCALING:VT:ALL 1
[:INPut]:SCALing:{VT|CT|SFACtor}:
ELEMent<x>
Function
Sets or queries the VT ratio, CT ratio, or power
coefficient of the specified element.
Syntax
[:INPut]:SCALing:{VT|CT|SFACtor}
:ELEMent<x> {<NRf>}
[:INPut]:SCALing:{VT|CT|SFACtor}
:ELEMent<x>?
<x> = 1 to 3 (element)
<NRf> = 0.001 to 9999.
Example
:INPUT:SCALING:VT:ELEMENT1 1
:INPUT:SCALING:VT:ELEMENT1?
-> :INPUT:SCALING:VT:ELEMENT1 1.000
[:INPut]:SYNChronize
Function
Sets or queries the synchronization source.
Syntax
[:INPut]:SYNChronize
{VOLTage|CURRent|OFF}
[:INPut]:SYNChronize?
Example
:INPUT:SYNCHRONIZE VOLTAGE
:INPUT:SYNCHRONIZE?
-> :INPUT:SYNCHRONIZE VOLTAGE