Communication Query Errors (400 to 499)
Error in communication Query
Code
Message
Query INTERRUPTED.
410
Query UNTERMINATED.
420
Query DEADLOCKED.
430
Query UNTERMINATED after indefinite response. Do not write a query after *IDN? or *OPT?.
440
System Communication Errors (300 and 399)
Error in System Operation
Code
Message
Communication device-specific error.
300
399
Fatal error in the communication driver.
Communication Warning (50)
Warning
Code
Message
50
*OPC/? exists in message.
Other Errors (350, 390)
Code
Message
350
Queue overflow.
390
Overrun error (RS-232 only)
Note
Code 350 occurs when the error queue overflows. This error is only returned in response to a :STATus:
ERRor? query; it is never displayed on the screen.
IM WT310E-17EN
Corrective Action
Check the transmission and reception order.
Check the transmission and reception order.
Keep program messages to 1024 bytes or less in length,
including <PMT>.
Corrective Action
Servicing is required.
Servicing is required.
Corrective Action
Write *OPC or *OPC? at the end of program messages. —
Corrective Action
Read the error queue.
Decrease the baud rate.