YOKOGAWA WT310EH User Manual page 43

Digital power meter communication interface
Hide thumbs Also See for WT310EH:
Table of Contents

Advertisement

Command
NUMeric Group
:NUMeric?
:NUMeric:FORMat
:NUMeric:NORMal?
:NUMeric[:NORMal]:VALue?
:NUMeric[:NORMal]:NUMber
:NUMeric[:NORMal]:ITEM<x>
:NUMeric[:NORMal]:PRESet
:NUMeric[:NORMal]:CLEar
:NUMeric[:NORMal]:DELete
:NUMeric[:NORMal]:HEADer?
:NUMeric:LIST?
:NUMeric:LIST:VALue?
:NUMeric:LIST:NUMber
:NUMeric:LIST:ORDer
:NUMeric:LIST:SELect
:NUMeric:LIST:ITEM<x>
:NUMeric:LIST:PRESet
:NUMeric:LIST:CLEar
:NUMeric:LIST:DELete
:NUMeric:HOLD
RATE Group
:RATE
:RATE:AUTO?
:RATE:AUTO:TIMeout
:RATE:AUTO:SYNChronize
RECall Group
:RECall:NUMber?
:RECall[:NORMal]:VALue?
:RECall:LIST:VALue?
:RECall:PANel
STATus group
:STATus?
:STATus:CONDition?
:STATus:EESE
:STATus:EESR?
:STATus:ERRor?
:STATus:FILTer<x>
:STATus:QENable
:STATus:QMESsage
:STATus:SPOLl?
IM WT310E-17EN
Function
Queries all numeric data output settings.
Sets or queries the numeric data format.
Queries all numeric data output settings.
Queries the numeric data.
Sets or queries the number of numeric data items that are transmitted by the
:NUMeric[:NORMal]:VALue? command.
Sets or queries the specified numeric data output item (function, element,
and harmonic order).
Presets the numeric data output item pattern.
Clears numeric data output items (sets the items to NONE).
Deletes numeric data output items.
Queries the numeric data header.
Queries all harmonic measurement numeric list data output settings.
Queries the harmonic measurement numeric list data.
Sets or queries the number of numeric list data items that are transmitted by
:NUMeric:LIST:VALue?.
Sets or queries the maximum output harmonic order of the harmonic
measurement numeric list data.
Sets or queries the output components of the harmonic measurement
numeric list data.
Sets or queries the output item (function and element) of the specified
harmonic measurement numeric list data item.
Presets the harmonic measurement numeric list data output item pattern.
Clears harmonic measurement numeric list data output items (sets the items
to NONE).
Deletes harmonic measurement numeric list data output items.
Sets or queries the on/off (hold/release) status of the numeric data hold
feature.
Sets or queries the data update interval.
Queries all applicable settings for when the data update interval is set to
Auto.
Sets or queries the timeout for when the data update interval is set to Auto.
Sets or queries the synchronization source for when the data update interval
is set to Auto.
Queries the number of blocks of measured data that is stored.
Queries the numeric data at the specified block number.
Queries the numeric list data of harmonic measurement at the specified
block number.
Loads a setup parameter file.
Queries all the settings for the communication status feature.
Queries the contents of the condition register.
Sets or queries the extended event enable register.
Queries the contents of the extended event register and clears the register.
Queries the error code and message of the last error that has occurred (top
of the error queue).
Sets or queries the transition filter.
Sets or queries whether messages other than errors will be stored to the
error queue (ON) or not (OFF).
Sets or queries whether message information will be attached to the
response to the STATus:ERRor? query (ON/OFF).
Executes serial polling.
6.1 List of Commands
Page
6-19
6-19
6-19
6-19
6-19
6-20
6-20
6-20
6-20
6-20
6-21
6-21
6-21
6-21
6-21
6-22
6-22
6-22
6-22
6-23
6-29
6-29
6-29
6-29
6-30
6-30
6-30
6-30
6-31
6-31
6-31
6-31
6-31
6-31
6-31
6-31
6-31
6-3
1
2
3
4
5
6
7
8
9
App
Index

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wt332eWt310eWt333e

Table of Contents