Setting Up The Meter (Setup); Setting Numeric Values; Setting The Decimal Point (Dec. P T) - YOKOGAWA YPP6820 Instruction Manual

Explosion-proof loop-powered rate/totalizer
Table of Contents

Advertisement

YPP6820 Explosion-Proof Loop-Powered Rate/Totalizer

Setting Up the Meter (SETUP)

The Setup menu is used to select:
1.
Rate and total decimal point position
2.
Program menu
3.
Rate and total tag display
4.
Time base
5.
Total conversion factor
6.
Manual or automatic total reset function
Press the Enter button to access any menu or press
Up arrow button to scroll through choices.
Press the Menu button to exit at any time.

Setting Numeric Values

The numeric values are set using the Right and Up
arrow buttons.
Press Right arrow to select next digit and Up arrow
to increment digit.
The digit being changed blinks.
Press the Enter button, at any time, to accept a
setting or MENU button to exit without saving
changes.
The decimal point is set using the Right or Up arrow
button in the Setup-decimal point menu.

Setting the Decimal Point (dec. P T)

Rate decimal point may be set with up to four decimal
places or with no decimal point at all. Total decimal
point may be set with up to six decimal places or with
no decimal point at all. Rate decimal and total decimal
are programmed individually.
Pressing the Right arrow moves the decimal point
one place to the right until no decimal point is
displayed.
Pressing the Up arrow moves the decimal point one
place to the left.