9.1

SYSTEM REPORTS

9.2
O/C RPTS
NO
9.3
RESTORAL
NO YES
DISARM
CellCom -LTE-V Series Installation and Programming Guide
System Reports
System Reports
This function allows you to select which reports the communicator sends to the receiver.

Opening/Closing Reports

YES
NO: Opening/Closing Reports are not sent.
YES: Opening/Closing Reports for each programmed area are sent. (Default is YES)

Zone Restoral Reports

This option allows you to specify whether the communicator sends zone restoral reports
and when they will be sent.
NO: Restoral reports are not sent by the communicator.
YES: The communicator always sends zone restoral reports at the time the zone restores
from an alarm or trouble condition.
DISARM: The communicator sends zone restoral reports when a zone that has
restored from an alarm or trouble is disarmed. Twenty-four hour zones send restorals
immediately.