Programming the CellCom-LTE-V Series Universal Alarm Communicator
5.1
Before You Begin
Before beginning programming, we recommend you read through the contents of this guide. The information in
this guide allows you to quickly learn the programming options and operational capabilities of the CellCom-LTE-V
Series Universal Alarm Communicator.
After this Introduction, the remaining sections describe the functions of each programming menu items along
with their available options. The communicator contains all of its programming information in an on-board
processor and does not require an external programmer.
In addition to this manual, you should also be familiar with the following documents:
•
CellCom-LTE-V Series Universal Alarm Communicator User Sheet (LT-1819)
•
CellCom-LTE-V Series Universal Alarm Communicator Programming Sheet (LT-1818)
Programming Sheet
Included with each communicator is the CellCom-LTE-V Series Programming Sheet (LT-1333).The programming
sheet lists the various options available for programming the communicator. Before beginning programming,
completely fill out the programming sheet with the programming options you intend to enter into programming.
Having the completed the programming sheet available to you while entering data helps to prevent errors and
can shorten the length of time you spend programming. Completing the programming sheet also provides you
with an accurate account of the communicator's program that you can keep on file for future system service or
expansion.
5.2
Getting Started
Initializing the Communicator
When programming a communicator for the first time or rewriting the entire program of an existing
communicator, use the Initialization programming option described in Section 6. Initializing clears the
communicator's memory of all data and sets the highest numbered user number to user code 99.
Accessing the Programmer
To access the programmer function of the communicator:
1. Connect the keypad to the PROG header
2. Press and release the RESET button.
3. Enter the code 6653 (PROG) and the keypad displays PROGRAMMER.
5.3
Programming Menu
You are now ready to start programming the CellCom-LTE-V Series Universal Alarm Communicator. Press the CMD
key to advance through the programming menu items listed in Table 4. To select a menu item for programming,
press any select key or area when the desired menu item displays on the keypad. The detailed instructions for
each programming step are found in this guide.
Menu Item
Initialization
Communication
Messaging Setup
Remote Options
System Reports
System Options
CellCom -LTE-V Series Installation and Programming Guide
PROGRAMMING INTRODUCTION
Section in This Manual
6
7
8
9
10
11
Table 4: Programming Menu Items
Menu Item
Section in This Manual
Output Options
Area Information
Zone Information
Stop
Set Lockout Code
Z-Wave Setup
12
13
14
15
16
17
Digital Monitoring Products