System Options
System Options
This section allows you to select system wide parameters used in the operation of the
communicator system. A description of each System Option follows:
Entry Delay 1
30
Enter the entry delay time for all exit type zones programmed. When an armed Exit type
zone is faulted, the area must be disarmed before the entry delay expires or a fault will
be detected. All burglary type zones are delayed along with the Exit zone. Entry delay
times can be from 30 to 250 seconds. Default is 30 seconds.
Exit Delay
60
Enter the Exit Delay time for all Exit type zones. When the exit delay time starts, all
activity on exit and burglary zones is ig nored until the exit delay expires. During Exit
Delay, if an exit zone trips, then restores, and trips again, the Exit Delay timer restarts.
This restart can occur only once. Exit delay times can be from 30 to 250 seconds.
Default is 60 seconds.
Exit Error Operation: At arming, when an entry/exit zone (EX) is faulted at the end of
the exit delay then a zone alarm and an Exit Error are sent to the receiver.
Cross Zone Time
0
Enter the time allowed between zone faults. When a zone programmed for cross zoning
faults, the communicator begins counting down the Cross-Zone Time entered here. If the
same zone or another cross-zoned zone faults within this time, an alarm report is sent to
the receiver.
If the Cross-Zone Time expires without the second zone fault, only a zone fault report
from the first zone is sent to the receiver. The Cross-Zone Time can be from 4 to 250
seconds in one second increments. Enter 0 (zero) to disable the Cross-Zone Time
feature. See the Appendix - Cross Zoning.
Power Fail Delay
1
This option tracks the duration of a primary power failure. The delay time can be from 1
to 9 hours. When the power is off for the length of the programmed delay time, a power
failure report is sent to the receiver. For example, if the power failure delay is set for
two hours, then the power failure report will be sent between 2-3 hours. Entering a 0
(zero) sends the power failure report within 15 seconds.
Swinger Bypass Trips
2
Enter the number of times (1-6) a zone can go into an alarm or trouble condition within
one hour be fore being auto matically bypassed. Bypassed zones are auto matically reset
when the area they are assigned to is disarmed. All 24-hour zones are reset when any
area of the system is dis armed. A programming Stop operation restores a bypassed zone.
Entering 0 (zero) disables this function. Default is 2.
How it works
The communicator hour timer starts at 59 minutes past the hour. If the hour timer
expires before the trip counter is exceeded, the trip counter returns to 0 (zero). If the
trip counter is exceeded before the hour expires, the zone is auto matically bypassed by
the communicator. A Bypass Re port is sent to the receiver if Bypass Re ports is YES.
Reset Swinger Bypass
YES
When YES is selected, an auto matically bypassed zone is reset if it remains in a normal
condition for one complete hour after being bypassed. A report of the automatic reset is
sent to the receiver. Default is NO.