12.1
AREA INFORMATION
12.2
AREA NO: -
12.3
* UNUSED *
12.4
NO
AUTO ARM
12.4.1
BAD ZONES:
BYP
FORC
12.5
NO
AUTO DIS
CellCom -LTE-V Series Installation and Programming Guide
Area Information
Area Information
This section allows you to assign functions to the area of the communicator. All non-
24-hour zones must be assigned to an active area. See Zone Information for more
information.
Area Number
Enter the number of the area to program. Select from areas 1 to 6.
Area Name
Only those areas given names can have zones assigned to them. All others are marked
*UNUSED*. See Entering Characters and Special Characters.
To add an area name to the system, press any select key or area and enter up to
16 characters for the new name. Press CMD to continue. To mark an active area as
unused, delete the old name by pressing any Select key then press the CMD key. The
communicator automatically sets the name as *UNUSED*. If you have already Initialized
the communicator, all areas will be marked as *UNUSED*.
Automatic Arming
YES
Select YES to allow this area to arm automatically according to the opening and closing
schedule.
At arming, faulted zones are handled according to the option selected in Bad Zones. If
a Closing report is sent, the user number is indicated as SCH on the SCS-1R or SCS-VR
Receivers. Select NO to disable automatic arming for this area. Default is NO.
Bad Zones
BYP
At the time of automatic arming, some zones in the area may not be in a normal
REF
condition. This option allows you to program the panel's response to these bad zones.
This option is not displayed if AUTO ARM is NO.
BYP: All bad zones are bypassed. A report of the bypass is sent to the receiver if Bypass
Reports has been selected as YES. The report indicates SCH as the user number.
FORC: All bad zones are force armed. Zones force armed in a bad condition are capable
of restoring into the system and reporting alarms if tripped. A report of the force arm is
sent to the receiver. The report indicates the user number as SCH.
REF: The automatic arming is refused and no arming takes place. Closing report is sent
to the receiver.
Automatic Disarming
YES
NO disables automatic disarming by schedule for this area. Select YES to allow this area
to automatically disarm according to a schedule. If an Opening report is sent to the
receiver, the user number is indicated as SCH.