GATEWAY ADDR
192.168.0.1
SUBNET MASK
255.255.255.0
DNS SERVER
0.0.0.0
PROGRAMMING
2001
PORT

REMOTE OPTIONS

REMOTE OPTIONS
RMT KEY:
DISARM
NO
YES
APP KEY:

SYSTEM REPORTS

SYSTEM REPORTS
O/C RPTS NO YES
RESTORAL
NO YES
DISARM
Digital Monitoring Products
22
GATEWAY ADDRESS
Enter the local gateway address. The gateway IP address is needed to exit the local
network. The default gateway address is 192.168.0.1.
SUBNET MASK
Enter the local subnet mask assigned to the communicator. The default subnet mask
address is 255.255.255.000.
DNS SERVER
Enter the IP address of the DNS (Domain Name System) used by the communicator to
resolve domain names into IP addresses. The default address is 0.0.0.0.
PROGRAMMING PORT
Enter the programming port number. The programming port identifies the port used to
communicate messages to and from the communicator. The default programming port
setting is 2001.
REMOTE OPTIONS
This option allows you to enter the information needed for remote command/remote
programming operation.
REMOTE KEY
Enter a code of up to eight digits for use in verifying the authority of a receiver to perform
a remote command/programming session. The receiver must give the correct key to the
communicator before access will be granted. All communicators are shipped from the
factory with the remote key preset as blank.
To enter a new remote key, press any select area and enter any combination of up to
8 digits. The numbers you enter appear as asterisks.
REMOTE DISARM
Choose YES to enable the communicator to be disarmed remotely. The default is YES.
Choose NO to disable remote disarming.
APP KEY
Enter the 8‑digit app key obtained in your dealer settings on Dealer Admin
(DMPDealerAdmin.com). This option is a security feature of the Virtual Keypad app and is
used only when your dealer settings have "EASYconnect" set as the communication type.
This option is used to eliminate the need for a static IP address programmed in network
options. To enter a new App Key, press any select area and enter any combination of
8 digits. The default is blank.
SYSTEM REPORTS
This option allows you to select which reports the communicator sends to the receiver.
OPENING/CLOSING REPORTS
Choose NO to prevent sending opening/closing reports.
Choose YES to send opening/closing reports for each programmed area. The default is
YES.
ZONE RESTORAL REPORTS
Specify whether the communicator sends zone restoral reports and when they will be sent.
Choose NO to prevent sending restoral reports from the communicator.
Choose YES to enable the communicator to send zone restoral reports when a zone
restores from an alarm or trouble condition. The default is YES.
Note: The communicator sends zone restoral reports when a zone restored from an
alarm or trouble is disarmed. Twenty‑four hour zones send restorals immediately.