Enter Output Sequence

If you are using bar codes to create your output sequence, scan Enter Output
Sequence to begin scanning your string.

Partial Sequence

If an output sequence operation is terminated before all your output sequence cri-
teria are met, the bar code data acquired to that point is a "partial sequence." You
can define how partial sequences are output using the same types of command
strings you used to create output sequences.
Partial Sequence Example - Three Symbologies with <> Separators, but with a
Damaged Code
In this example, you are scanning PDF417, Code 128, and Code 39 bar codes, and
you want the scanner to output Code 39 first, Code 128 second, and PDF417 third,
in brackets, as shown below, but the Code 39 bar code has been damaged and can-
not be output.
You would use the same command line as shown in
Three Symbologies with <> Separators
Solaris 7980g User Guide
SEQBLK
62
9999
43
FF
6A
9999
Enter Output Sequence
(page 57):
sequence editor start command
code identifier for Code 39
code length that must match for Code 39, 9999 = all
lengths
start character match for Code 39, 43h = "C"
termination string for first code
code identifier for Code 128
code length that must match for Code 128, 9999 = all
lengths
Output Sequence Example 2 -