UPC/EAN Version

Scan the UPC/EAN Version On bar code to decode GS1 Composite symbols that
have a U.P.C. or an EAN linear component. (This does not affect GS1 Composite
symbols with a GS1-128 or GS1 linear component.) Default = UPC/EAN Version Off.
Note: If you scan coupons that have both UPC and GS1 DataBar codes, you may wish to
scan and output only the data from the GS1 DataBar code. See
Output
GS1 Composite Code Message Length
Scan the bar codes below to change the message length. Refer to
Description
= 1-2435. Minimum Default = 1, Maximum Default = 2435.
Minimum Message Length

GS1 Emulation

The scanner can automatically format the output from any GS1 data carrier to
emulate what would be encoded in an equivalent GS1-128 or GS1 DataBar sym-
bol. GS1 data carriers include UPC-A and UPC-E, EAN-13 and EAN-8, ITF-14, GS1-
128, and GS1-128 DataBar and GS1 Composites. (Any application that accepts
GS1 data can be simplified since it only needs to recognize one data carrier type.)
If GS1-128 Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8, EAN13)
are expanded out to 16 digits. If the AIM ID is enabled, the value will be the GS1-
128 AIM ID, ]C1 (see
If GS1 DataBar Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8,
EAN13) are expanded out to 16 digits. If the AIM ID is enabled, the value will be the
GS1-DataBar AIM ID, ]em (see
136
UPC/EAN Version On
(page 115) for further information.
(page 92) for additional information. Minimum and Maximum lengths
Symbology Charts
on page 221).
Symbology Charts
on page 221).
* UPC/EAN Version Off
Coupon GS1 DataBar
Message Length
Maximum Message Length