SIS Configuration
and Control
The scaler can be configured and controlled with Extron Simple Instruction Set (SIS)
commands when connected to a host computer or other device (such as a control system).
Attach the host device to the rear panel RS-232 connector, the LAN port, or the front
panel USB port. Commands can be entered using a Telnet application such as the Extron
DataViewer, available at
This section describes SIS communication and control. Topics in this section include:
The scaler uses a protocol of 9600 baud, one stop bit, eight data bits, no parity, and no flow
control (see

Host and Scaler Communication

SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command sequence. When the scaler determines that a
command is valid, it executes the command and sends a response to the host device.
All responses from the scaler to the host end with a carriage return and a line feed
(CR/LF = ] ), indicating the end of the response character string (one or more characters).

Scaler-Initiated Messages

When a local event such as a front panel selection or adjustment takes place, the scaler
responds by sending a message to the host. No response is required from the host.
Example scaler-initiated messages are listed here.

Copyright Information

The copyright message is displayed upon connecting to a scaler via TCP/IP or Telnet or
after a power cycle via RS-232 and depends on the scaler model.
]
60-nnnn-nn
Ddd, DD MMM YYYY HH:MM:SS
Vn.nn
60-nnnn-nn
YYYY
www.extron.com
Host and Scaler Communication
SIS Overview
Command and Response Table
Remote RS-232 connector
X!
] (where X! is the input number during an input switch).
In
All
] The scaler sends this response when an input is switched or when a new
Reconfig
signal is detected.
X@] The scaler sends this response when a hot plug event on output X@ is
HplgO
detected.
© Copyright YYYY, Extron Electronics, IN1608 xi <model>, Vn.n,
]
] (day, date, and time as in
is the firmware version number.
is the model part number.