Reset Modes - Extron electronics IN1608 xi IPCP SA with LinkLicense User Manual

In1608 xi series scaling presentation switchers
Table of Contents

Advertisement

Reset Modes

The IN1608 xi series have three reset modes (numbered 1, 4, and 5).
These resets are available by pressing the recessed
the rear panel (see
Summary table for a description of the reset modes.
You can also perform resets using SIS commands (see the
commands
Series PCS Help file).
ATTENTION:
NOTE: The reset modes listed close all open IP and Telnet connections and all sockets.
Mode
Activation
1
Using an Extron Tweeker or other small
screwdriver, press and hold in the
recessed Reset button for 30 seconds
while applying power to the scaler.
After a mode 1 reset,
NOTE:
update the device with the latest
firmware version. DO NOT
operate with the firmware version
that results from this mode reset.
This temporarily resets the device
to factory default until power is
recycled. To use factory default
firmware, upload that version
again.
4
Hold down the Reset button until the
Reset LED blinks twice (approximately
6 seconds). Then, press Reset
momentarily (less than 1 second).
5
Hold down the Reset button
until the Power LED blinks 3 times
(approximately 9 seconds). Then,
press Reset momentarily (less than
1 second).
in the image at right). See the Reset Mode
A
on page 71) and PCS (see the IN1606 and IN1608
Review the reset modes carefully. Using the wrong reset mode may result in
unintended loss of flash memory programming, port reassignment, or processor
reboot.
Étudier de près les différents modes de réinitialisation. Appliquer le mauvais mode
de réinitialisation peut causer une perte inattendue de la programmation de la
mémoire flash, une reconfiguration des ports ou une réinitialisation du processeur.
Each mode is a separate function, not a continuation from mode 1 to mode 5.
Reset Mode Summary
The device reverts to the factory default
firmware.
Firmware reverts to the factory default for a
single power cycle.
All user files and settings (drivers, audio
and video adjustments, IP settings, and so
on) are maintained.
NOTE:
firmware or perform a mode 1 reset by
mistake, cycle power to the device to
return to the firmware version running
prior to the reset.
IP settings revert to factory defaults.
Port mapping reverts to factory default.
DHCP turns off.
IP address is set to 192.168.254.254.
Reset LED blinks four times in quick
succession during reset.
The device reverts to the factory defaults
except for firmware.
Mode 4 results are performed.
All user modifiable configurations reset to
default values including IP settings and
real-time adjustments.
All user loaded files are deleted.
The Reset LED blinks 4 times in quick
succession during the reset.
button on
Reset
Reset
Result
If you do not want to update the
IN1608 xi Scaling Presentation Switcher • Operation
AMPLIFIED OUTPUT
2x25W(8Ω)/2x50W(4Ω)
L
R
OUTPUTS
O
1
2
CLASS 2 WIRING
REMOTE
LAN
VARIABLE
RESET
L
R
RS-232
Tx Rx
G
IN1608 xi SA
A
Purpose/Notes
Use mode 1 to revert
to the factory default
version if incompatibility
issues arise with
user-loaded firmware.
Use mode 4 to reset
all IP settings back to
factory defaults.
Use mode 5 to
restart with default
configuration. This
is equivalent to SIS
command ZQQQ.