2.5

Main circuit terminals

2.5.1

Details on the main circuit terminals

Terminal symbol Terminal name
R/L1, S/L2, T/L3
AC power input
U, V, W
Inverter output
P/+, N/-
Brake unit connection
Earth (ground)
2.5.2
Terminal layout of the main circuit terminals,
wiring of power supply and the motor
FR-CS84-012 and 022
FR-CS82S-025, 042
N/-
R/L1 S/L2 T/L3
Power supply
FR-CS84-120 and 160
N/- P/+
R/L1 S/L2 T/L3
Power supply
NOTE
• Make sure the power cables are connected to the R/L1, S/L2, and T/L3. However, the FR-CS82S is not equipped with terminal
T/L3. (Phase need not be matched.) Never connect the power cable to the U, V, and W of the inverter. Doing so will damage
the inverter.
• Connect the motor to U, V, and W. (The phases must be matched.)
Terminal function description
Connect these terminals to the commercial power supply.
Do not connect anything to these terminals when using the high power
factor converter (FR-HC2) or the power regeneration common
converter (FR-CV).
Connect a three-phase squirrel-cage motor to these terminals.
Connect the brake unit (FR-BU2), power regeneration common
converter (FR-CV), or high power factor converter (FR-HC2) to these
terminals.
For earthing (grounding) the inverter chassis. Be sure to earth (ground)
the inverter.
P/+
M
Motor
M
Motor
FR-CS84-036 to 080
FR-CS82S-070, 100
N/-
P/+
R/L1 S/L2 T/L3
Power supply
FR-CS84-230 to 295
R/L1 S/L2 T/L3
N/- P/+
Power supply
Refer to
page
42
33
M
Motor
M
Motor
2. INSTALLATION AND WIRING
2.5 Main circuit terminals
1
2
3
5
5
6
7
8
9
10
31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents