Pr.75
setting
The reset command can always be
0
input.
The reset command can be input only
1
when the protective function is
activated.
The reset command can always be
2
input.
The reset command can be input only
3
when the protective function is
activated.
14 (initial
The reset command can always be
value)
input.
The reset command can be input only
15
when the protective function is
activated.
The reset command can always be
16
input.
The reset command can be input only
17
when the protective function is
activated.
 Reset selection (P.E100)
• When
= "1, 3, 15, or 17", the reset command can be input (by turning ON the RES signal or via communication) only
Pr.75
when the protective function is activated.
NOTE
• When the RES signal is input during operation, the motor coasts since the inverter being reset shuts off the output. Also, the
cumulative values of electronic thermal O/L relay and regenerative brake duty are cleared.
• The reset command by pressing the Reset key on PU can be input only when the protective function is activated, regardless
of the Pr.75 setting.
 Disconnected PU detection (P.E101)
• If the inverter detects that the enclosure surface operation panel (FR-PA07) / LCD operation panel (FR-LU08) / parameter
unit (FR-PU07) is disconnected from the inverter for 1 second or longer while
"E.PUE" (PU disconnection fault) is displayed and the inverter output is shut off.
NOTE
• When the FR-PA07/LU08/PU07 has been disconnected since before power-ON, the output is not shut off.
• To restart the inverter, confirm that the FR-PA07/LU08/PU07 is connected before reset.
• If the FR-PA07/LU08/PU07 is disconnected during PU JOG operation while Pr.75 = "0, 1, 14, or 15" (operation continues even
when the PU is disconnected), the inverter decelerates to a stop .
• During RS-485 communication operation via the PU connector, the setting for the reset selection and the PU stop selection is
enabled, but the setting for the disconnected PU detection is disabled. (The communication is checked according to the setting
of Pr.122 PU communication check time interval.)
 PU stop selection (P.E102)
• The PU stop function (deceleration stop of the inverter by pressing
PU, External, or Network when Pr.75 = "14 to 17".
• When the inverter is stopped by using the PU stop function, the indication "
is not provided.
• When Pr.75 = "0 to 3", deceleration stop of the inverter by pressing
86
5. PARAMETERS
5.3 (E) Environment setting parameters
Reset selection
Operation continues even when
PU is disconnected.
Inverter output shut off when PU
is disconnected.
Operation continues even when
PU is disconnected.
Inverter output shut off when PU
is disconnected.
Disconnected PU detection
on the PU) is enabled in any operation mode of
PU stop selection
The inverter decelerates to a stop only when
is pressed in the PU operation mode.
The inverter decelerates to a stop when
pressed in any operation mode of the PU,
External, or Network.
= "2, 3, 16, or 17", the indication
Pr.75
" is displayed on the PU. A fault output
is enabled only in the PU operation mode.
is